DP Physics (last assessment 2024)

Test builder »

Question 19M.3.HL.TZ2.aiii

Select a Test
Date May 2019 Marks available [Maximum mark: 1] Reference code 19M.3.HL.TZ2.aiii
Level HL Paper 3 Time zone TZ2
Command term Calculate Question number aiii Adapted from N/A
aiii.
[Maximum mark: 1]
19M.3.HL.TZ2.aiii

An ultrasound A-scan is performed on a patient.

Ultrasound of intensity 50 mW m-2 is incident on a muscle. The reflected intensity is 10 mW m-2. Calculate the relative intensity level between the reflected and transmitted signals.

[1]

Markscheme

Examiners report

The question was generally well answered with a few candidates simply taking the ratio of intensities instead of 10x log ratio (Intensity level)