DP Physics (last assessment 2024)
Question 19N.3.HL.TZ0.14a(i)
Date | November 2019 | Marks available | [Maximum mark: 3] | Reference code | 19N.3.HL.TZ0.14a(i) |
Level | HL | Paper | 3 | Time zone | TZ0 |
Command term | Show that | Question number | a(i) | Adapted from | N/A |
a(i).
[Maximum mark: 3]
19N.3.HL.TZ0.14a(i)
An X-ray beam, of intensity , is used to examine the flow of blood through an artery in the leg of a patient. The beam passes through an equal thickness of blood and soft tissue.
The thickness of blood and tissue is 5.00 mm. The intensity of the X-rays emerging from the tissue is and the intensity emerging from the blood is .
The following data are available.
Mass absorption coefficient of tissue = 0.379 cm2 g–1
Mass absorption coefficient of blood = 0.385 cm2 g–1
Density of tissue = 1.10 × 103 kg m–3
Density of blood = 1.06 × 103 kg m–3
(a(i))
Show that the ratio is close to 1.
[3]
Markscheme
AND ✔
✔
✔