DP Physics (first assessment 2025)
Question 22N.2.SL.TZ0.a.i
Date | November 2022 | Marks available | [Maximum mark: 3] | Reference code | 22N.2.SL.TZ0.a.i |
Level | SL | Paper | 2 | Time zone | TZ0 |
Command term | Determine | Question number | a.i | Adapted from | N/A |
a.i.
[Maximum mark: 3]
22N.2.SL.TZ0.a.i
Determine the minimum area of the solar heating panel required to increase the temperature of all the water in the tank to 30°C during a time of 1.0 hour.
[3]
Markscheme
energy required = 250 × 4200 × (30 − 15) ✓
energy available = 0.30 × 680 × t × A ✓
A = «» 21 «m2» OR 22 «m2» ✓
Allow ECF from MP1 and MP2.
Accept the correct use of 0.30 in either MP1 or MP2.
Examiners report
Most candidates had a good attempt at this but there were often slight slips. Some missed the efficiency of the process. Some included the albedo of the roof tiles. Some thought that the temperature rise needed to have 273 added to convert to kelvin. However, sometimes scoring through ECF (error carried forward), the average mark was around 2 marks.